Cleanroom Floor

Cleanroom Floor

Product features

PVC sheets or rolls optional

PVC sheets or rolls optional

1703674957PVC sheets or rolls optional

1703674225Easy installation and durable

1703673402Provide comfortable work space

Cleanroom Floor

Epoxy floor available, ESD type optional

Resistance in 106~109Ω to control statics

Dust-proof and durable, allow for forklift movement

Anti-static PVC sheets or rolls available

Anti-static PVC sheets or rolls available

Resistance in 106~109Ω to control statics

Dust-proof and easy to clean, suitable for cleanroom

Cleanroom Floor

PVC Flooring Installation Drawing

Anti-static PVC contains copper foil and conductive adhesive

Cleanroom Floor

Raised floor with grilled surface to balance air flow

ESD surface optional to control statics

PVC Flooring Installation Drawing

PVC Flooring Installation Drawing

Anti-static PVC contains copper foil

and conductive adhesive

PVC Floor Color Card

PVC Floor Color Card

Anti-static PVC Color Card

Anti-static PVC Color Card

Epoxy Floor Color Card

Epoxy Floor Color Card

Specification

Product PVC Roll PVC Sheet
Thickness 2-3mm 2-3mm
Size 20X2m 600X600mm
Weight 2.85-5kg/m2 3.8-5.8kg/m2
ESD resistance(ESD type) 106-109Ω 106-109Ω
Size deviation ≤0.40% ≤0.10%
Anti-wear capacity 0.014g/cm2 0.014g/cm2
Anti-wear performance T<2.0mm3 T<2.0mm3
Load bearing test 3000kg 3000kg
Chemical resistance Good Good

Recent Projects

Frequently Asked Questions

1.Why can't existing concrete floor be used directly as the cleanroom floor?

A cleanroom has extremely high requirements for environment hygiene and cleanliness, while a concrete floor cannot meet these requirements. The reason is that a concrete floor is prone to cracking, and these cracks can hide dust and dirt, which cannot be thoroughly cleaned, thus destroying the dust-free environment of the cleanroom. In addition, a concrete floor does not have enough hardness, it can be easily scratched by sharp objects, and long-term friction on its surface can generate dust particles, which directly disrupt the cleanliness.

2.What is the most cost-effective cleanroom floor?

Among cleanroom floors, the price of ordinary 2mm PVC sheet flooring is the lowest. For the same specification, anti-static flooring adds around 10~15% to the cost. Converting the same specification sheets to rolls type increases the price by about 50~55%. Ordinary 2mm epoxy flooring is approximately 10~15% more expensive than ordinary 2mm PVC sheet flooring. Converting ordinary epoxy to anti-static epoxy increases the cost by around 45~50%.

3. Why is epoxy resin used as a cleanroom floor?

This is mainly due to its excellent adhesion, acid and alkali resistance, wear resistance, impact resistance , mold resistance, dust-proofing, and anti-slip properties. Epoxy resin floors come in bright and varied colors, are easy to clean, and can effectively reduce the generation and spread of dust and contaminates, maintaining the cleanliness and hygiene of the indoor environment. Additionally, epoxy resin floors provide electrostatic discharge(ESD) functionality, which makes them capable of meeting the high standards required for flooring materials in cleanrooms.

4. What is cleanroom raised floor?

Cleanroom raised floor is a special type of floor used in cleanroom environments. The design and installation of this type of floor aim to provide a clean and sterile working environment, suitable for places that require strict control over air cleanliness, such as semiconductor production facilities, precision module manufacturing areas, and precision aerospace manufacturing workshops.

5. Why is it not a good idea to lay carpet near a cleanroom?

Laying carpet near a cleanroom is not advisable because carpet tends to accumulate large amounts of dust, bacteria, mold, mites, and other microorganisms. These accumulations can become sources of contamination in the cleanroom air. Additionally, without regular and proper cleaning, the carpet can become a breeding ground for bacteria and mold, which may adversely affect the health of the cleanroom staff.

6. How to clean the cleanroom floor?

The key to cleaning a cleanroom floor involves using specialized cleaning tools and following specific cleaning procedures;

①Use dedicated mops and cleaning agents: use mops and cleaning agents that are specifically designed for cleanrooms to clean the floor, storing them separately from regular tools;

②Vacuum: Before mopping, thoroughly vacuum the floor using a specialized vacuum cleaner equipped with a HEAP Filter;

③Regular Waxing: Waxing should be conducted strictly and systematically to maintain the cleanliness of the floor and prevent the accumulation of static electricity;

④Inspection and documentation: After each cleaning session, perform a comprehensive inspection anddocument the results;

⑤Precautions: Always remember to wipe from top to bottom when working to avoid cross-contamination.‌‌

Which product suits you most?

Comply with GMP Standard

GMP standards

20X2m

Size

2-3mm

Thickness

B-s1

Fire resistance

106-109Ω

ESD resistance(ESD type)

0.014

Anti-wear

idely used in Bio&Pharma and electronic cleanroom

Application

Comply with GMP Standard

GMP standards

600X600mm

Size

2-3mm

Thickness

B-s1

Fire resistance

106-109Ω

ESD resistance(ESD type)

0.014

Anti-wear

idely used in Bio&Pharma and electronic cleanroom

Application

Comply with GMP Standard

GMP standards

600X600mm

Size

35mm

Thickness

A

Fire resistance

104-109Ω

ESD resistance(ESD type)

0.1

Anti-wear

uitable for ISO4-5 cleanroom, electric room

Application

Comply with GMP Standard

GMP standards

N/A

Size

2-3mm

Thickness

B-s1

Fire resistance

106-109Ω

ESD resistance(ESD type)

0.03

Anti-wear

idely used in Bio&Pharma and electronic cleanroom

Application